On-site water miscible fluids testing
On-site water miscible tests for quick results corrective actions ( systems treatment)
- Appearance
- Deposit, sediments and pollution contents
- Concentration of emulsions and solutions
- Tramp oil content
- PH of the diluted oil
- Alkaline reserve
- Presence of aerobic bacteria, fungi & yeasts
- Presence of sulfate reducing anaerobic bacteria
- Residual corrosion protection capability of metals
- Water hardness
- Water PH
- Water nitrate contents
- Water nitrite contents
- Temperature
- Comprehensive technical evaluation reports performing
Support for representative tests kit selection for every segment/application
 
| Lubricants & fluids analysis characteristics and testing methods : | Method | Standard | Kinematic viscosity @ 40 °C | ASTM D 7279-08 | Kinematic viscosity @ 100°C | ASTM D 7279-08 | Viscosity index | ASTM D 2270-10e1 | Water content | in-house | Dispersance | ASTM D 7899-13 | Soot content | ASTM D 7899-13 | ICP elements | ASTM D 5185-09 | Base number (BN) | ASTM D 2896-11 | Acid number (AN) | ASTM D 664-11a | Ferrous magnetic residues (PQ) | in-house | Flash point (CCCFP) | ASTM D 6450-05(2010) | i-pH | in-house | IR test | in-house | Soot content | in-house | Oxidation | in-house | Nitration | in-house | Appearance | in-house | Cleanliness class ISO | ISO 4406:1999 | Mechanical contamination (cu filtrare pe hartie filtranta de 0,8 microni) | in-house | Foaming tendency SI/SII | ASTM D 892-11a | pH | ASTM D 1287-11 | Refractive index at 20°C | ISO 5661:1983 | Density at 15°C | ASTM D 4052-11 |
|
Specific sampling procedure performing
Extended experts diagnose and corrective actions reports